title: "High-resolution variable-density 3D cones coronary MRA. | Sutter Health"
description: "Coronary MR angiography with isotropic submillimeter spatial resolution and high temporal resolution can be performed with VD 3D cones to improve the depiction of coronary arteries."
url: "https://www.sutterhealth.org/research/publications/high-resolution-vary-density-3d-cones-coronary-mra-1055312425"
---

1.  [Home](https://www.sutterhealth.org/) /
2.  [Research](https://www.sutterhealth.org/research) /
3.  [Research Publications](https://www.sutterhealth.org/research/publications) /
4.  High-resolution variable-density 3D cones coronary MRA.

# High-resolution variable-density 3D cones coronary MRA.

Addy NO, Ingle RR, Wu HH, Hu BS, & Nishimura DG.

_Magn Reson Med. 74(3):614-21. doi: 10.1002/mrm.25803. Epub 2015 Jul 14._

2015-09-01

## Abstract

PURPOSE: To improve the spatial/temporal resolution of whole-heart coronary MR angiography by developing a variable-density (VD) 3D cones acquisition suitable for image reconstruction with parallel imaging and compressed sensing techniques.

METHODS: A VD 3D cones trajectory design incorporates both radial and spiral trajectory undersampling techniques to achieve higher resolution. This design is used to generate a VD 3D cones trajectory with 0.8 mm/66 ms isotropic spatial/temporal resolution, using a similar number of readouts as our previous fully sampled cones trajectory (1.2 mm/100 ms). Scans of volunteers and patients are performed to evaluate the performance of the VD trajectory, using non-Cartesian L1 -ESPIRiT for high-resolution image reconstruction.

RESULTS: With gridding reconstruction, the high-resolution scans experience an expected drop in signal-to-noise and contrast-to-noise ratios, but with L1 -ESPIRiT, the apparent noise is substantially reduced. Compared with 1.2 mm images, in each volunteer, the L1 -ESPIRiT 0.8 mm images exhibit higher vessel sharpness values in the right and left anterior descending arteries.

CONCLUSION: Coronary MR angiography with isotropic submillimeter spatial resolution and high temporal resolution can be performed with VD 3D cones to improve the depiction of coronary arteries.

[PubMed abstract](http://www.ncbi.nlm.nih.gov/pubmed/26172829)

![Bob S Hu, M.D.](https://dyn.mktgcdn.com/p/OLtyV-80yDbOmh0GcQI3xnNzxEtgLP1RmJcZvvKP3u4/fit=crop,gravity=auto,dpr=2,width=188,height=250,quality=100)

Bob S Hu, M.D.

Principal investigator

[View profile](https://www.sutterhealth.org/research/investigators/bob-s-hu-md-1049681033)

## Research topics

-   [Cardiovascular Diseases](https://www.sutterhealth.org/research-search-results?query=%22%5C%22Cardiovascular+Diseases%5C%22%22)
-   [Disease Management](https://www.sutterhealth.org/research-search-results?query=%22%5C%22Disease+Management%5C%22%22)

## Related publications

[View all publications](https://www.sutterhealth.org/research-search-results?verticalKey=research_publication)

-   Publication
    
    ### [Cardiovascular magnetic resonance phase contrast imaging.](https://www.sutterhealth.org/research/publications/cardiovasc-mri-phase-contrast-1055312458)
    
    Nayak KS, Nielsen JF, Bernstein MA, Markl M, D Gatehouse P, M Botnar R, Saloner D, Lorenz C, Wen H, S Hu B, Epstein FH, N Oshinski J, Raman SV.
    
    J Cardiovasc Magn Reson. 17(1):71. doi: 10.1186/s12968-015-0172-7.
    
    2015 Aug 09
    
-   Publication
    
    ### [Whole-heart coronary MR angiography using a 3D cones phyllotaxis trajectory.](https://www.sutterhealth.org/research/publications/whole-heart-coronary-mr-angiography-1055312405)
    
    Malavé MO, Baron CA, Addy NO, Cheng JY, Yang PC, Hu BS, Nishimura DG.
    
    Magn Reson Med. doi: 10.1002/mrm.27475. \[Epub ahead of print\]
    
    2018 Oct 29
    
-   Publication
    
    ### [Non-contrast-enhanced peripheral angiography using a sliding interleaved cylinder acquisition.](https://www.sutterhealth.org/research/publications/noncontrast-enhance-periph-angiog-use-slincyl-1055312471)
    
    Kwon KT, Kerr AB, Wu HH, Hu BS, Brittain JH, Nishimura DG.
    
    Magn Reson Med. 74(3):727-38. doi: 10.1002/mrm.25452. Epub 2014 Sep 9.
    
    2015 Sep 01
    
-   Publication
    
    ### [Off-resonance-robust velocity-selective magnetization preparation for non-contrast-enhanced peripheral MR angiography.](https://www.sutterhealth.org/research/publications/off-reson-robust-veloc-select-magnetiz-prep-mra-1055312480)
    
    Shin T, Hu BS, Nishimura DG.
    
    Magn Reson Med. 70(5):1229-40. doi: 10.1002/mrm.24561. Epub 2012 Nov 28.
    
    2013 Nov 01
    
-   Publication
    
    ### [3D image-based navigators for coronary MR angiography.](https://www.sutterhealth.org/research/publications/3d-image-navig-ht-mr-angiography-1055312459)
    
    Addy NO, Ingle RR, Luo J, Baron CA, Yang PC, Hu BS, Nishimura DG.
    
    Magn Reson Med. doi: 10.1002/mrm.26269. \[Epub ahead of print\]
    
    2016 May 13
    

[View all publications](https://www.sutterhealth.org/research-search-results?verticalKey=research_publication)

```json
{"@context":"https://schema.org","@type":"MedicalOrganization","name":"Sutter Health","@id":"https://www.sutterhealth.org/#medicalorganization","url":"https://www.sutterhealth.org","logo":"https://www.sutterhealth.org/static/images/sutter-health-logo.svg","address":{"@type":"PostalAddress","streetAddress":"2200 River Plaza Drive","addressLocality":"Sacramento","addressRegion":"CA","postalCode":"95833","addressCountry":"US"},"areaServed":{"@type":"AdministrativeArea","name":"California"},"sameAs":["https://www.facebook.com/SutterHealth","https://www.instagram.com/sutterhealth/","https://x.com/SutterHealth","https://www.youtube.com/sutterhealth","https://www.linkedin.com/company/sutter-health","https://en.wikipedia.org/wiki/Sutter_Health"]}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","@id":"https://www.sutterhealth.org/research/publications/high-resolution-vary-density-3d-cones-coronary-mra-1055312425#breadcrumblist","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.sutterhealth.org/"},{"@type":"ListItem","position":2,"name":"Research","item":"https://www.sutterhealth.org/research"},{"@type":"ListItem","position":3,"name":"Research Publications","item":"https://www.sutterhealth.org/research/publications"},{"@type":"ListItem","position":4,"name":"High-resolution variable-density 3D cones coronary MRA."}]}
```

```json
{"@context":"https://schema.org","@type":"MedicalScholarlyArticle","@id":"https://www.sutterhealth.org/research/publications/high-resolution-vary-density-3d-cones-coronary-mra-1055312425#medicalscholarlyarticle","name":"High-resolution variable-density 3D cones coronary MRA.","headline":"High-resolution variable-density 3D cones coronary MRA.","abstract":"PURPOSE: To improve the spatial/temporal resolution of whole-heart coronary MR angiography by developing a variable-density (VD) 3D cones acquisition suitable for image reconstruction with parallel imaging and compressed sensing techniques. METHODS: A VD 3D cones trajectory design incorporates both radial and spiral trajectory undersampling techniques to achieve higher resolution. This design is used to generate a VD 3D cones trajectory with 0.8 mm/66 ms isotropic spatial/temporal resolution, using a similar number of readouts as our previous fully sampled cones trajectory (1.2 mm/100 ms). Scans of volunteers and patients are performed to evaluate the performance of the VD trajectory, using non-Cartesian L1 -ESPIRiT for high-resolution image reconstruction. RESULTS: With gridding reconstruction, the high-resolution scans experience an expected drop in signal-to-noise and contrast-to-noise ratios, but with L1 -ESPIRiT, the apparent noise is substantially reduced. Compared with 1.2 mm images, in each volunteer, the L1 -ESPIRiT 0.8 mm images exhibit higher vessel sharpness values in the right and left anterior descending arteries. CONCLUSION: Coronary MR angiography with isotropic submillimeter spatial resolution and high temporal resolution can be performed with VD 3D cones to improve the depiction of coronary arteries.","description":"Coronary MR angiography with isotropic submillimeter spatial resolution and high temporal resolution can be performed with VD 3D cones to improve the depiction of coronary arteries.","keywords":["Cardiovascular Diseases","Disease Management"],"datePublished":"2015-09-01","url":"https://www.sutterhealth.org/research/publications/high-resolution-vary-density-3d-cones-coronary-mra-1055312425","inLanguage":"en-US","identifier":[{"@type":"PropertyValue","propertyID":"PMID","value":"26172829"},{"@type":"PropertyValue","propertyID":"DOI","value":"10.1002/mrm.25803"}],"sameAs":["https://pubmed.ncbi.nlm.nih.gov/26172829/","https://doi.org/10.1002/mrm.25803"],"isPartOf":{"@type":"Periodical","name":"Magn Reson Med"},"author":[{"@type":"Person","name":"Addy NO"},{"@type":"Person","name":"Ingle RR"},{"@type":"Person","name":"Wu HH"},{"@type":"Person","@id":"https://www.sutterhealth.org/research/investigators/bob-s-hu-md-1049681033","name":"Hu BS","url":"https://www.sutterhealth.org/research/investigators/bob-s-hu-md-1049681033"},{"@type":"Person","name":"Nishimura DG"}],"sourceOrganization":{"@type":"MedicalOrganization","name":"Palo Alto Medical Foundation Research Institute"},"about":[{"@type":"DefinedTerm","name":"Cardiovascular Diseases","url":"https://www.sutterhealth.org/research-search-results?facets=%5B%7B%22i%22%3A%22c_researchTopics.name%22%2C%22v%22%3A%5B%22Cardiovascular+Diseases%22%5D%7D%5D&verticalKey=research_publication"},{"@type":"DefinedTerm","name":"Disease Management","url":"https://www.sutterhealth.org/research-search-results?facets=%5B%7B%22i%22%3A%22c_researchTopics.name%22%2C%22v%22%3A%5B%22Disease+Management%22%5D%7D%5D&verticalKey=research_publication"}],"mainEntityOfPage":{"@type":"WebPage","@id":"https://www.sutterhealth.org/research/publications/high-resolution-vary-density-3d-cones-coronary-mra-1055312425","breadcrumb":{"@id":"https://www.sutterhealth.org/research/publications/high-resolution-vary-density-3d-cones-coronary-mra-1055312425#breadcrumblist"}}}
```